Intergas Heating Ltd
45
9.2 Other faults
9.2.1 Burner does not ignite
Remove air form gas pipe.
Gas supply pressure too low.
Contact the gas supply company.
Replace ignition electrode.
No spark. Ignition unit on gas valve faulty.
Check the cabling. Check the spark plug cap. Replace the ignition unit.
Gas/air adjustment not correctly set.
Check adjustment. See gas/air adjustment.
Check the wiring. Check the fuse , if necessary, replace the
Replace the gas valve. Re
adjust the gas valve, see gas/air adjustment
9.2.2 Burner ignites noisily
Gas supply pressure too high.
The house pressure switch
may be faulty. Contact the gas company.
Incorrect ignition gap.
Replace the ignition pin.
Check the ignition electrode gap.
Gas/air adjustment not correctly set.
Check the setting. See gas/air adjustment.
Replace the ignition electrode.
Replace the ignition unit on the gas valve.
Pin must touch test tool
Pin must not touch test tool
Checking ignition pin position using test