7.3 Setting and adjusting the clock functions
7.3.1 Setting the clock
Press the button for less than 1 second and repeat this untill ‘’24hr clock’’
appears. For adjusting the clock to the correct time press the [+] or [-] button.
Note: Holding the button for more than 1 second will make the clock run fast.
7.3.2 Setting the timer function
On pressing the button for more than 2 seconds the clock display will flash.
The time for each on/off shows in the clock display and the service display shows which on 1 and 3 OR off 2 and 4 time is being set.
Pressing the button again will change between the different on/off switching periods.
The pre-set times are as follows:
Display : [06:00] and [1] Start first period CH on.
[09:00] and [2] End first period CH off.
[16:00] and [3] Start second period CH on.
[22:00] and [4] End second period CH off.
By pressing the button the new times will be stored in the boiler controller.
In the service display [P] appears.
When the clock is in period [1] or [3] (CH ON) the clock symbol LED is on.
When the clock is in period [2] or [4] (CH not active) the LED is on.
By pressing the button over 5 seconds the default setting for the switch moments will be restored.
In the service display “F-set” appears.
By pressing the button the boiler controller will return to the normal situation without storing any changes.
7.4 Additional functions
Pressing the button for less than 1 second the following additional functions can be activated:
- t-on (temporary on).
The boiler will respond on every CH demand from the room thermostat until the next
switch moment.
- c-on (continuous on).
The boiler will respond on every CH demand from the room thermostat without any
time limit.
- OFF
The boiler will not respond on any CH demand from the room thermostat.
7.5 Shutting down
CAUTION
Drain the appliance and the installation if mains power has
been interrupted and there is a possibility of freezing.
1. Drain the appliance at the drain tap.
2. Drain the installation at the lowest point.
3. Close the main cock for the water supply to the DHW section.
4. Drain the appliance by removing the DHW couplings below the appliance.

Table of Contents

Other manuals for Intergas Rapid 25

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intergas Rapid 25 and is the answer not in the manual?

Intergas Rapid 25 Specifications

General IconGeneral
Boiler TypeCombi
DHW Output25 kW
Efficiency Rating93%
Flow Rate10.2 l/min
MountingWall Mounted
ERP EfficiencyA
Max Gas Rate2.78 m³/h
Dimensions (H x W x D)590 x 450 x 240 mm

Related product manuals