Intergas Heating Ltd 36
E
Min. supply temperature during OT
demand
(OT = OpenTherm stat)
40
4
0
Setting range 10°C to 60°C. If the OT
thermostat
demands a supply temperature that is below this
set value, the heat demand cannot be met.
E.
OT reaction
1
1
0 = Ignore OT demand if < value par E
1 = If OT demand < par E than OT demand = par.
E
2 = Enable OT
F
Starting speed CH
60
50
Setting range 50 to 99%
F
.
Starting speed DHW
60
5
0
Setting range 50 to 99%
H
Max. fan speed
45
45
Setting range 40 to 50 (40 = 4000 rpm, 50 = 5000
rpm) The absolute maximum speed can be set
through this parameter.
n
Flow temperature during heating
DHW cylinder
85
85
Setting range 60°C to 90°C
n
.
Eco/Comfort
DHW
temperature
(keep hot facility)
0
0
Setting range 0, 40
65 °C
0 = temperature is equal to DHW temperature
setting
40 – 65 = absolute temperature
O
.
Delay time CH
0
0
Setting range 0 = 15
minutes
o
Delay time CH after DHW
0
0
Setting range 0
15 minutes.
o
.
Eco Days
3
3
Setting range : 0
10
0 = Keep hot facility controlled by Open therm
room thermostat
1 – 10 eco days.
P
Minimum switch off time during CH
operation
5
5
Setting range 0
to 10 minutes (anti cycling
function)
P
.
DH
W
coefficient
30
36
Setting range 0, 24, 30, 30
0 = Applicable for combi boilers with flow switch
24 = not applicable
30 = Rapid 25
36 = Rapid 30
q
Summer mode
0
0
0 = Summer mode inactive
1 = Summermode to be set in display
Text in display : Su
2 = Summermode to be set in display
Text in display : So
3 = Summermode to be set in display
Text in display : Et
r
Heating curve coefficient
0
0
Not applicable.
8.3.1 Enable/disable keep hot facility by Open Therm room thermostat.
It is possible to enable and disable the keep hot facility of the boiler by using an Open Therm room
thermostat. For this the boiler needs to be set in Eco mode : ( LED on).
Also the parameter o. needs to be set to 0. In this setting the adaptive behaviour of the boiler (see §
8.1.2 ) is disabled.
The Open Therm room thermostat will now enable or disable the keep hot facility (provided
that the room thermostat supports this function)
8.3.2 Summer mode.
When parameter q is set to a value unlike 0 it is possible to activate summer mode. During
Summer mode a request for Central Heating will be ignored. This mode does not affect the
delivery of DHW.
Summer mode can be activated by pressing the on/off button until the text, corresponding
with the setting of parameter q appears in the display,
Pressing the on/off button again will end the summer mode and set the boiler in stand-by
modus (sequence is off/on/summer/off ..etc).

Table of Contents

Other manuals for Intergas Rapid 25

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intergas Rapid 25 and is the answer not in the manual?

Intergas Rapid 25 Specifications

General IconGeneral
Boiler TypeCombi
DHW Output25 kW
Efficiency Rating93%
Flow Rate10.2 l/min
MountingWall Mounted
ERP EfficiencyA
Max Gas Rate2.78 m³/h
Dimensions (H x W x D)590 x 450 x 240 mm

Related product manuals