ThesensitivityoftheLTSmayneedtobeadjustedaccordingtoambi-
entlightconditionsandre
ectivecharacteristicsofthebacksideofthe
media.ThisisdoneintheSetupMode(PrintDefs/LTS),seeChapter7.
YoucanalsocheckthattheLTSworksproperly.
TheLTSsetupoptionsareonlydisplayedifanoptionallabeltaken
sensorisinstalledintheprinter.
LTS Adjust
Press<Enter>.Alabelisfedout.Removethelabelandpress<Enter>
again.Amenushowsthesensitivityautomaticallyselectedbythe
rm-
wareandtherange,inwhichtheLTSwillwork.Press<Enter>againand
youwillproceedtotheLTSTestmenu.
LTS Test
Press<Enter>.Alabelisfedout.Removethelabelandanewlabel
shouldbefedoutautomatically.RepeatuntilyouaresuretheLTSworks
properly.Thenpress<Enter>tostopandexit.
LTS Value
Press<Enter>.Youcanenteranewvalueintherangeindicatedinthe
LTSAdjustmenu(seeabove).Min/maxvaluesareintherange0to10.