EasyManua.ls Logo

INVT Goodrive 200 - Page 121

INVT Goodrive 200
253 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive200 inverters Function codes
120
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modify
time
P24.10
Valid
auxiliary
motor
P24.10~P24.12
can make three motors to form a
simple system of water supply.
P08.09 is used to select the valid auxiliary motor.
0: No auxiliary motor
1: Auxiliary motor 1 valid
2: Auxiliary motor 2 valid
3: Auxiliary motor 1 and 2 valid
Setting range of P24.10: 0.0~3600.0s
Setting range of P24.11: 0.0~3600.0s
0
P24.11
Start/stop
delay time of
auxiliary
motor 1
5.0s
P24.12
Start/stop
delay time of
auxiliary
motor 2
5.0s
P24.13
Reserved
0~1 0
P24.14
Reserved
0~1
0

Table of Contents

Related product manuals