Goodrive200 inverters Fault tracking
190
E-DP
Profibus
communication
fault
1. Communication address
is not correct.
2. Corresponding resistor is
not dialed
3. The files of main stop
GSD does not set sound
Check related setting
E-NET
Ethernet
communication
fault
4. The Ethernet address is
not set right.
5. The Ethernet
communication is not
selected to right.
6. The ambient interference
is too strong.
1. Check the relative setting.
Check the communication
method selection.
2. Check the environment
and avoid the interference.
E-CAN
CAN
communication
fault
1. The connection is not
sound
2. Corresponding resistor is
not dialed
3. The communication is
uneven
1. Check the connection
2. Draw out the correspond
resistor
3. Set the same baud rate
8.6 Common fault analysis
8.6.1 The motor does not work