Goodrive200 inverters Basic operation instruction
132
Function
code
Name
Detailed instruction of parameters Default
value
P04.28 Keypad setting voltage
0.0%~100.0%(the rated voltage of
motor)
100.0%
P04.29 Voltage increasing time
0.0~3600.0s 5.0s
P04.30 Voltage decreasing time
0.0~3600.0s 5.0s
P04.31 Maximum output voltage
P04.32~100.0%(the rated voltage of
motor)
100.0%
P04.32 Minimum output voltage
0.0%~P04.31(the rated voltage of motor)
0.0%
7.4 Parameters of the motor
Physical accident may occur if the motor starts up suddenly during
autotune. Please check the safety of surrounding environment of the
motor and the load before autotune.
The power is still applied even the motor stops running during static
autotune. Please do not touch the motor until the autotune is
completed, otherwise there would be electric shock.
Do not carry out the rotation autotune if the motor is coupled with the
load, please do not operate on the rotation autotune. Otherwise
misaction or damage may occur to the inverter or the mechanical
devices. When carry out autotune on the motor which is coupled with
load, the motor parameter won’t be counted correctly and misaction
may occur. It is proper to de-couple the motor from the load during
autotune when necessary.
Goodrive200 series inverters can drive both asynchronous motors and synchronous motors. And
at the same time, they can support two sets of motor parameters which can shift between two
motors through multi-function digital input terminal or communication.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive 200 and is the answer not in the manual?

INVT Goodrive 200 Specifications

General IconGeneral
Protection Class/Enclosure RatingIP20
Cooling MethodForced air cooling
Communication Protocol/InterfacesModbus
Braking UnitBuilt-in or external (optional)
Protection FeaturesOvercurrent, overvoltage, undervoltage, overload, short circuit, overheating
Ambient Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
Humidity≤95% RH (non-condensing)
AltitudeBelow 1000m, derated use above 1000m

Related product manuals