Goodrive200 inverters Basic operation instruction
146
Function
code
Name
Detailed instruction of parameters Default
value
frequency)
P17.14 Digital adjustment 0.00Hz~P00.03 0.00Hz
7.7 Analog input
Goodrive200 series inverters have three analog input terminals and 1 high-speed pulse input
terminals (of which, AI1 and AI2 are 0~10V/0~20mA and Al can select voltage input or current input
by J1, A2 can select voltage input or current input by J2 and AI3 is for -10~10V ) as the standard
configuration. The inputs can be filtered and the maximum and minimum values can be adjusted.
AI1
AI3
HDI
P05.32
P05.33
P05.34
P05.35
P05.42
P05.43
P05.44
P05.45
P05.46
P05.47
P05.50
P05.51
P05.52
P05.53
P05.48
P05.36
P05.54
P17.15
P17.17
P17.18
AI2
P05.37
P05.38
P05.39
P05.40
P05.41
P17.16
P05.00
HDI input type selection 
0
1
1
2
0
P05.49
HDI high speed pulse input function selection 
AI1 input voltage
AI2 input voltage
AI3 input voltage
HDI input frequency
AI3
AI1/AI2/HDI
P05.00
0: HDI is high speed pulse input
1: HDI is switch input
P05.49
0: frequency se tting input
1: counter input
2: length counter input
Analog curve input setting
Analog input filter

Table of Contents