Goodrive200 inverters Basic operation instruction
124
Note: If fault occurs, please do as the “Fault Tracking”. Estimate the fault reason and settle the
issue.
Besides P00.01 and P00.02, terminal command setting can also used to set the running command
channel.
Current runnig
command
channel
P00.01
Multi-function
terminal 36
Shifting the
command to keypad
Multi-function
terminal 37
Shifting the
command to
communication
Multi-function
terminal 38
Shifting the
command to
communication
Keypad runnig
command
channel
/
Terminal runnig
command channel
Communication
runnig command
channel
Terminal runnig
command
channel
Keypad runnig
command channel
/
Communication
runnig command
channel
Communication
runnig command
channel
Keypad runnig
command channel
Terminal runnig
command channel
/
Note: “/” means the multi-function terminal is invalid on the current reference channel.
Relative parameters table:
Function
code
Name Detailed instruction of parameters Default
value
P00.00 Speed control mode 2:V/F control (applying to AM) 0
P00.01 Run command channel
0:Keypad running command
channel(LED off)
1:Terminal running command channel
(LED flickering)
2:Communication running command
channel (LED on);
0
P00.18
Function
restore parameter
0:No operation
1:Restore the default value
2:Clear fault records
0
P00.15 Motor parameter 0:No operation 0