Goodrive200 inverters Basic operation instruction
134
autotune on the other motor.
Relative parameters list:
Function
code
Name Detailed instruction of parameters
Default
value
P00.01 Run command channel
0:Keypad running command
channel(“LOCAL/REMOT” light off)
1:Terminal running command channel
(“LOCAL/REMOT” flickering)
2:Communication running command
channel (“LOCAL/REMOT” on)
0
P00.15
Motor parameter
autotuning
0:No operation
1:Rotation autotuning
2:Static autotuning 1
3:Static autotuning 2
0
P00.17 Motor type
0:G type
1:P type
0
P02.01
Asynchronous motor 1
rated power
0.1~3000.0kW
Depend
on model
P02.02
Asynchronous motor 1
rated frequency
0.01Hz~P00.03(the Max frequency) 50.00Hz
P02.03
Asynchronous motor 1
rated speed
1~36000rpm
Depend
on model
P02.04
Asynchronous motor 1
rated voltage
0~1200V
Depend
on model
P02.05
Asynchronous motor 1
rated current
0.8~6000.0A
Depend
on model
P02.06
Asynchronous motor 1
stator resistor
0.001~65.535Ω
Depend
on model
P02.07
Asynchronous motor 1
rotor resistor
0.001~65.535Ω
Depend
on model
P02.08
Asynchronous motor 1
leakage inductance
0.1~6553.5mH
Depend
on model
P02.09 Asynchronous motor 1 0.1~6553.5mH Depend

Table of Contents