Function Instructions
0 Running frequency 0~the Max. output frequency
1 Set frequency 0~ the Max. output frequency
2 Ramp reference frequency
0~ the Max. output frequency
3 Running rotation speed
0~2 times of the rated synchronous rotation speed of
the motor
4
Output current (relative to the
inverter)
0~2 times of the rated current of the inverter
5
Output current (relative to the
motor)
0~2 times of the rated current of the inverter
6 Output voltage 0~1.5 times of the rated voltage of the inverter
7 Output power 0~2 times of the rated power
8 Set torque 0~2 times of the rated current of the motor
9 Output torque 0~2 times of the rated current of the motor
10 AI1 0~10V/0~20mA
11 AI2 0~10V/0~20mA
12 AI3 -10V~10V
13 HDI 0.00~50.00kHz
14
MODBUS communication set
value 1
-1000~1000,1000 corresponds to 100.0%
15
MODBUS communication set
value 2
-1000~1000,1000 corresponds to 100.0%
16~30 Reserved
Relative parameters list:
Function
code
Name
Detailed instruction of parameters Default
value
P06.00 HDO output
0:Open collector pole high speed pulse
output
1: Open collector pole output
0
P06.14 AO1 output
0
P06.15 AO2 output
0
P06.16 HDO high-speed pulse
0:Running frequency
1:Set frequency
2:Ramp reference frequency
0