Goodrive35 inverters Function codes
135
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
detection
P11.15
Speed
deviation
detection
time
This parameter is used to see the speed deviation
detection time
Setting range: 0.0~10.0s
1.0s
P11.16
Open loop
vector and
VF 0Hz
output
0:Invalid
1:Valid; ensure rated output torque when voltage
drop
0
P12 Group Motor 2
P12.00
Motor type
2
0:Asynchronous motor
1:Synchronous motor
Note: switch the current motor by the switching
channel of P08.31.
0
P12.01
Rated
power of
asynchron
ous motor
2
0.1~3000.0kW
Set the parameter of
the controlled
asynchronous motor.
In order to ensure the
controlling
performance, set the
P12.01~P12.05
according to the name
plate of the
asynchronous motor.
Goodrive35 series
inverters provide the
Depend
on
model
P12.02
Rated
frequency
of
asynchron
ous motor
2
0.01Hz~P00.03(the Max.
frequency)
50.00
Hz
P12.03
Rated
1~36000rpm
Depend
www.barghmaher.ir