Goodrive35 inverters Basic operation instruction
217
Set
value
Function
Instructions
57
Motor overtemperature fault
input
The motor will stop when fault occurs.
58
Rigid tapping enable
The mode is enabled if the terminal is valid
59
Switch to SVPWM control
If the terminal is valid in stopping mode, it will switch
to V/F control
60
Switch to FVC control
If the terminal is valid in stopping mode, it will switch
to FVC control
61
PID pole switching
The terminal is used with P09.03 to switch the output
pole
62
Undervoltage stopping input
The terminal and the enabling bit is valid, the inverter
will stop at the time sst by P08.05
63
Reversed
Relative parameters list:
Function
code
Name
Detailed instruction of parameters
Default
value
P05.00
HDI input selection
0: High pulse input
1: Digital input
0
P05.01
S1 terminals function
selection
0: No function
1: Forward rotation operation
2: Reverse rotation operation
3: 3-wire control operation
4: Forward jogging
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Operation pause
9: External fault input
10:Increasing frequency setting(UP)
11:Decreasing frequency
setting(DOWN)
12:Frequency setting clear
1
P05.02
S2 terminals function
selection
4
P05.03
S3 terminals function
selection
7
P05.04
S4 terminals function
selection
0
P05.05
S5 terminals function
selection
0
P05.06
S6 terminals function
selection
0
P05.07
S7 terminals function
selection
0