Loading...
Goodrive35 inverters Function codes
78
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
frequency
of forward
rotation
P03.15=1.
Setting range:0.00 Hz~P00.03 (the Max. output
frequency)
P03.17
Keypad
setting for
upper
frequency
of reverse
rotation
50.00
Hz
P03.18
Upper
electromoti
on torque
source
This function code is used to select the
electromotion and braking torque upper-limit setting
source selection.
0:Keypad setting upper-limit frequency(P03.20 sets
P03.18, P03.21 sets P03.19)
1: AI1
2: AI2
3: AI3
4: HDI
5:MODBUS communication
6:PROFIBUS/CANopen communication
7:Ethernet communication
Note: setting mode 1~7,100% corresponds to three
times of the motor current.
0
P03.19
Upper
braking
torque
source
0
P03.20
Keypad
setting of
electromoti
on
torque
The function code is used to set the limit of the
torque.
Setting range:0.0~300.0%(motor rated current)
180.0
%
P03.21
Keypad
setting of
braking
torque
180.0
%