Goodrive35 inverters Function codes
87
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
output
voltage
The setting range of P04.31:P04.32~100.0%
(the rated voltage of the motor)
The setting range of P04.32:0.0%~ P04.31
(the rated voltage of the motor)
%
P04.32
Minimum
output
voltage
0.0%
P05 Group Input terminals
P05.00
HDI input
selection
0: High pulse input. See P05.49~P05.54
1: Digital input. See P05.09
0
P05.01
S1
terminals
function
selection
0: No function
1: Forward rotation operation
2: Reverse rotation operation
3: 3-wire control operation
4: Forward jogging
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Operation pause
9: External fault input
10:Increasing frequency setting(UP)
11:Decreasing frequency setting(DOWN)
12:Frequency setting clear
13:Shift between A setting and B setting
14:Shift between combination setting and A setting
15:Shift between combination setting and B setting
16:Multi-step speed terminal 1
17:Multi-step speed terminal 2
18:Multi-step speed terminal 3
19:Multi- step speed terminal 4
1
P05.02
S2
terminals
function
selection
4
P05.03
S3
terminals
function
selection
7
P05.04
S4
terminals
function
selection
0
P05.05
S5
terminals
function
selection
0
www.barghmaher.ir