0x0000–0x1223
LED ones place:
0: Both the ∧/∨ key and digital potentiometer
can be used for the control.
1: Only the ∧/∨ key can be used for the
control.
2: Only the digital potentiometer can be used for
the control.
3: Neither the ∧/∨ key nor the digital
potentiometer can be used for the control.
Tens place: Frequency control selection
0: Valid only when P00.06=0 or P00.07=0
1: Valid for all frequency setting methods
2: Invalid for multi-step speed running when
multi-step speed running has the priority
LED hundreds place: Action selection for stop
0: Setting is valid.
1: Valid during running, cleared after stop
2: Valid during running, cleared after a stop
command is received
LED thousands place: Indicates whether to
enable the integral function through the ∧/∨
key and digital potentiometer.
0: Disable the integral function
1: Enable the integral function
0x000–0x221
Ones place: Frequency setting selection
0: The setting made through UP/DOWN is valid.
1: The setting made through UP/DOWN is
invalid.
Tens place: Frequency control selection
0: Valid only when P00.06=0 or P00.07=0
1: Valid for all frequency setting methods
2: Invalid for multi-step speed running when
multi-step speed running has the priority