CCI.TECUOperation
4.3.3.6.1 Calibrate
Proceed as follows to calibrate the voltage values for the 3-point hitch:
1. Press the "Calibrate" button (F3) on the touchscreen.
The calibration menu opens.
2. Lift the 3-point hitch to the maximum position and then press on the "MAX"
(F3) button on the touchscreen.
3. Lower the 3-point hitch to the minimum position and then press on the "MIN"
(F4) button on the touchscreen.
4. Confirm the values with "OK"
Note
A plausibility check is performed. An error message is given if, for example, the
minimum value exceeds the maximum value.
32