CCI.Cam – Troubleshooting
5 Troubleshooting
5.1 Terminal errors
The following overview shows possible terminal errors and how to solve them:
Error Possible cause Rectification
The terminal does not switch
on
• Terminal is not correctly
connected
• Check ISOBUS
connection
• Ignition is not switched
on.
• Start tractor.
The software of the connected
implement is not displayed
• Bus terminator missing
• Check resistance
• Software is loaded,
however is not displayed
• Check whether the
software can be
manually started from
the terminal start menu
• Connection error when
uploading the software
• Check physical
connection
• Contact the implement
manufacturer's customer
service
5.2 Error messages
The following overview shows error messages in CCI.Cam, their possible cause
and how to rectify them:
Error Possible cause Rectification
Video Multiplexer could not be
initialized.
Error at the cable connection Check the cable connection,
restart the terminal.
The required video source
could not be opened. (202)
Connection to the camera
lost/broken.
Check the cable connection,
restart the terminal.
The required camera could not
be mirrored.
Mirroring is not supported by the
camera (only occurs when using
the multiplexer).
Use a camera whose
hardware supports mirroring.
Error when creating the
screenshot. Please check
whether a flash drive has been
plugged in.
No flash drive plugged in. Plug in flash drive.
19