EasyManua.ls Logo

isobus VT50 - Page 136

isobus VT50
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CCI.TECUTroubleshooting
Invalid value!
PTO speed exceeds 3000
rpm.
Number of pulses per
rotation incorrect
Set the number of pulses
in the Power Take Off tab
PTO sensor defective Replace PTO sensor
Invalid value!
Speed (ground speed sensor)
exceeds 85 km/h.
Number of pulses per 100 m
incorrect
Set the number of pulses
in the setting menu
Ground speed sensor
defective
Replace ground speed
sensor
Invalid value!
Speed (wheel speed sensor)
exceeds 85 km/h.
Number of pulses per 100 m
incorrect
Set the number of pulses
in the setting menu
Wheel speed sensor
defective
Replace wheel speed
sensor
Calibration error
Invalid min. value!
New min. position is the same
or higher that the saved max.
position. Ensure that the min.
position is reached and the
saved max. position is valid.
Calibration sequence was not
observed.
Ensure that you have carried
out the calibration in the
correct sequence.
If the problem occurs again,
please contact your specialist
dealer.
The TECU switches to display
mode because a TECU of
higher priority has been
identified. Please check the
tractor settings.
Another TECU is connected to
the BUS. It is present in another
terminal or in your tractor.
If the other TECU makes the
necessary information
available, then it is correct that
CCI.TECU changes into
passive mode.
If you want to make the
information available with
CCI.TECU, then you must
deactivate the other TECU.
You can find more information
about this in the relevant
instruction manual.
Connection to Control could
not be established.
Data transfer has been
activated, but CCI.TECU could
not connect to the Task
Controller.
Check the status of the Task
Controller being used
(normally CCI.Control),
Note
Other error messages may be displayed on the terminal that are dependent on the
implement.
A detailed description of the possible error messages and troubleshooting can be
referred to in the implement operating instructions.
Note
If the implement cannot be operated, check whether the "stop switch" is pressed in.
The implement cannot be operated until the switch has been released.
Pos: 12 /C C-Is ob us/* *** Sei ten um bruc h *** * @ 8\mod_1274446340522_0.doc @ 121469 @
37