Service functions and error messages
Page 137
Meaning of the error message
Action: Check the connection wiring for the digital
outputs DOUT40 ... DOUT42 (short circuit, cross
circuit, etc.).
Check the connection wiring for the brake (short
circuit, cross circuit, etc.).
Brake connection: The error may occur with long
motor cables if:
1.
The brake output X6 was configured for
the brake (this is the case with factory
settings!) and
2.
A motor without a holding brake is used
and the brake connection lines in the
motor cable are terminated at X6. In
this case: Disconnect the brake
connection lines at X6.
If there is no error in the connection wiring, there
may be an internal error in the module (check by
swapping the module).
1 Digital inputs - Signal level error Cause: Exceeding / violation of discrepancy time with
multi-channel inputs (DIN40 ... DIN43, two-
handed control device, mode selector switch).