Electrical installation
Page 86
item C 1-Series
BR-
BR+
1
2
+24 V
Power supply
GND Power supply
Resistor and capacitor
for spark extinguishing
Motor with
holding brake
+24 V
Holding brake
GND Holding brake
Free-wheeling diode
Figure 19: Connecting a holding brake with high current draw (> 1A) to the device
The switching of inductive direct current via relay produces strong currents and sparking. For interference
suppression we recommend integrated RC suppressor elements, for example by Evox RIFA, denomination:
PMR205AC6470M022 (RC element with 22 in series with 0.47 µF).