Connection examples:
Sensor–Actual-value-signal Input
Connection of a 2-wire transducer
(e.g. standard pressure transducer PA22)
Connection of an active actual-value-signal
Possible connections:
Standard Pressure
Transducer PA22:
Actual-value-signal input 0/4-20mA: X3/4 … Sensor 2
+24VDC Sensor Supply: X3/3 brown
Actual-value-signal input 0/4-20mA: X3/2 … Sensor 1 white
Ground: X3/1
Switching between two connected sensors
Manual switching between two connected Sensors by closing Digital Input 1 (X3/9-10).
How to program see SUBMENU SENSORS [0400].
Digital Input 1