CENTRIFUGAL LIQUID CHILLER
WITH ECONOMIZER COMPRESSOR
CONTROL CENTER OPERATION Form 160.77-02 (611) Form 160.77-02 (1111)
R-134a
Issue Date:
November 15, 2011
MODEL YKEP
2700 - 3200 TON
LD15301a

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls York YKEP Series and is the answer not in the manual?

Johnson Controls York YKEP Series Specifications

General IconGeneral
BrandJohnson Controls
ModelYork YKEP Series
CategoryChiller
LanguageEnglish

Summary

Section 1 - YKEP Chiller Overview

Chiller Principle of Operation

Explains basic operation and configurations of the YKEP chiller.

Economizer Compressor Operation

Details start and stop criteria for the economizer compressor.

YKEP Oil Management

Describes the chiller's dedicated oil management system and its functions.

Capacity Control Operation

Explains the mechanisms and logic for controlling chiller capacity.

Major Capacity Control Devices

Identifies key components like PRVs and hot gas bypass valves.

Section 2 - YKEP Control Center Introduction

YKEP Control Center Overview

Introduces the integrated system for chiller monitoring and control.

Control Panel and Operator Interface

Details HMI hardware and how operators interact with the system.

Remote Control Capabilities

Outlines EMS integration and standard digital remote capabilities.

Section 3 - YKEP Control Panel Operation

Control Panel Display and Navigation

Describes the touch-screen interface, buttons, and methods for navigating screens.

Home and System Screen Overviews

Details the default display and general system status screen.

Compressor Operation and Calibration

Information on primary/economizer compressor screens and calibration procedures.

Capacity Control and Tuning

Explains capacity adjustment mechanisms, tuning, and limits.

Motor and Drive Screens

Information on EM Starter, MV SSS, and MV VSD motor interfaces.

Alarm, Trip, and Trending Screens

Covers monitoring and logging of faults, trips, and performance data.

Section 4 - Modbus RTU Slot List

Modbus RTU Communication Parameters

Details Modbus RTU slot list, parameters, and descriptions.

Section 5 - Display Messages

System Status and Warning Messages

Describes chiller operating states and general warning alerts.

Shutdown and Trip Messages

Explains conditions leading to shutdowns and critical faults.

Solid State Starter and VSD Faults

Details specific fault messages for motor starters and variable speed drives.

Tag Based Alarms

Lists specific alarms based on sensor readings and operating ranges.

SI Metric Conversion

Temperature Conversion

Explains how to convert Fahrenheit to Celsius for temperature values.