5.2.9 COMPASS SAFE DISTANCE:
In order to avoid unacceptable deviaon of the ships standard and steering compasses or magnetometer, the closest point of
the unit and the centre of the compass or magnetometer is govered by the table below.
So for example the minimum safe distance between the center of the steering compass and the cabinet is 220 cm.
Compass Safe Distance in cm:
Cabinet Control Unit MPA 1601 GA Alarm Panel MPA 1603
Standard 340 80 60
Steering 220 50 40
5.3 GENERAL ALARM ADJUSTMENT
The Compact MPA system has a facility for both curve form and frequency adjustment of the General Alarm.
This is a part of the system setup and must be determined either in the factory (FAT) or during System installaon and
commissioning. Conguraon of the GA characterisics is an opon within the MPA 1600 web conguraon facility, which is
described in secon 6.
This tone frequency and curve form alteraon facility is a conguraon selecon only open to Jotron or authorized
personnel.
5.4 FEEDBACK/INTERFERENCE CANCELLATION
In cases where loudspeakers are placed in the near proximity of the MPA 1601 Control unit (microphone) there is a possibility
of causing audible feedback making PA messages dicult or impossible to understand. The Compact MPA PA/GA system has
two dierent countermeasures in order to deal with this. Either a local mute facility in each MPA 1601 Control Unit, or by
using a temporary recording facility within the system in order to rst make a recording of the message, then automacally
replay the message when nished.
5.4.1 LOCAL MUTE
In the Control Unit, MPA 1601 there is a “local mute” relay and related terminals. The local loudspeakers object to the mute
funcon must be connected through this relay. As long as the Control unit is idle the relay are closed and all signal messages
are passing through to the local loudspeakers. Whenever the Control unit is acve (PA / Emergency PA) the relay opens and
the message is disconnected from the loudspeaker and it is locally muted. Whenever the Control Units becomes idle again
the loudspeaker is reconnected.
For connecon details see chapter 9.3.
5.4.2 TEMPORARY RECORDING
When this facility is enabled in the system conguraon, the Compact MPA system will not immediately output the message
when a PA or Emergency PA announcement is acvated, but start a temporary recording. When the PA / Emergency PA
announcement is nished the system automacally replays the message into the loudspeaker network in the selected zones
(according to the iniated zone selecon).
The temporary recording, or recording facility is selected individually per input during installaon or previously in a FAT
situaon. Once selected, it will be enabled for all messages inserted through this input. It is not dependant of any special or
addional connecons within the system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jotron MPA 1603 GA and is the answer not in the manual?

jotron MPA 1603 GA Specifications

General IconGeneral
Brandjotron
ModelMPA 1603 GA
CategoryMarine Equipment
LanguageEnglish

Related product manuals