34
User and Installaon Manual
Compact MPA
6.7 CONFIGURATION – USERS
Figure 9: Users
The “Users”-tab allows users to enable or disable access unit buses, set the paging priories between dierent buses and
enable or disable recording for paging events on individual buses. One bus may contain up to two 1601 and two 1603 access
units or up two 1605/1606 access units.
Each individual bus can be enabled or disabled. Disables buses will not trigger a general warning due to missing access units
on that parcular bus, so buses without connected access units should be disabled. The priority for each bus applies to pag-
ing messages, where 0 is the highest priority and increasing integers represent lower priories. A message with a lower pri-
ority cannot interrupt a message with higher priority. Recording can also be set up on the bus, controlling whether messages
shall be recorded in its enrety prior to playback.