Chapter 2  INSTALLATION OF THE SCANNER 
2.2  INSTALLATION PROCEDURE 
2-8 
Fig. 2.2-1      Improper way to hoist 
 
Fig. 2.2-2    X-band 
 
 Installation Procedure 
 Maintain a flat level surface on which to install the scanner. 
  Use sufficiently thick steel material and reinforcement material for the scanner's 
installation surface (mount base) to reduce vibration and impact. Keep the mount 
base flat and smooth. 
  If there is a partial gap between the mount base and the scanner chassis's legs, work 
on the installation surface so that it becomes flat and smooth, or make adjustments 
by inserting metal shims. 
If a gap exists and the scanner is tightly clamped, the chassis will distort and become 
damaged by vibration. 
 
 Avoid using vibration-proof rubber and resin 
  Do not insert an elastic body, such as vibration-proof rubber or resin, between the 
mount base and the scanner chassis' legs. If rubber or resin is inserted, the amplitude 
of vibration increases, resulting in the possibility of damage to the scanner. 
Furthermore, if installation bolts become loose due to deterioration of rubber or resin, 
the scanner may be damaged or fall from its mount. 
 
Wrap a cloth