Chapter 4 ADJUST MENU SETTINGS
4.5 ADJUSTING TT FUNCTION
4-17
4
NSTALLATION MANUAL
4.5 ADJUSTING TT FUNCTION
Adjusts TT function.
CAUTION
Do not change the quantization level settings unless absolutely
necessary. If set at an inappropriate value, the acquisition or
tracking function of the target tracking function (TT) deteriorates,
and this may lead to accidents.
"TT" operations
1 Open TT from the Adjust Menu.
"TT" menu appears.
4.5.1 VECTOR CONSTANT
Adjusts the vector target tracking capability of TT function.
The vector constant is adjusted to optimum value. Do not change the setting unless
absolutely necessary.
Note:
Do not change the setting unless absolutely necessary.
The vector constant shall be set to 4 normally. If the vector constant value
is higher, a target’s vector will be better followed up when the target and
own ship change their course or speed, but the vector accuracy will be
lower on the contrary.