Section 3 Common Basic Operations 3-14
[3] Active alert list
The alert of the highest priority is automatically selected. When an alert in the active alert list is
clicked on, the alert is selected.
The details of the selected alert are displayed in "[4] Details of active alert".
When a new alert is generated during the screen display, the alert is added at the top of the list.
By clicking on any of the items in the title line, active alerts can be sorted based on the item.
When the [ACK] button is clicked on, the alert is acknowledged.
Memo
The [ACK] button is not displayed for the [Caution] alert since acknowledgement is not required.
[4] Details of active alert
Details of the alert that is currently selected are displayed.
Alert
Detailed information
Cause:
Displays the cause of the alert.
Raised (UTC):
Displays the alert generation time.
Details:
Displays the details of the cause of the alert.
Advice:
Displays advice on the alert (action to be taken by the user).
Acknowledged (UTC):
Displays the time when the alert was acknowledged.
Category:
Displays the alert category.
Priority:
Displays the current alert priority (identification of Alarm/Warning/Caution).
Original Priority: Displays the priority (identification of Alarm/Warning/Caution) at the
generation of the alert.
[Higher] button The details of the alert of the higher priority than the alert that is currently
displayed appear.
[Lower] button The details of the alert of the lower priority than the alert that is currently
displayed appear.
[ACK] button
The alert that is currently selected is displayed.
[Alert History] tab
Alerts that have been generated in the past are displayed.
Up to 20 alerts are displayed per page.
When a newly acknowledged alert is generated during the screen display, the acknowledged alert is
added to the top of the list.
By clicking on any of the items in the title line, active alerts can be sorted based on the item.
Memo
The Alert History screen is displayed under the extended window only. A standard window is not
available.