C-7 Appendix C Setting the Inter switch
C.2.6 Using the set connection pattern
When connecting 3 to 8 radar antennas × 3 to 8 display units, it is possible to save the set connection
pattern in a file. By reading out the saved connection pattern when required, it is possible to quickly
change the connection pattern.
■ Saving a connection pattern
1 After setting a connection pattern, click the [Save/Load file] button of the [Inter Switch]
dialogue box.
The [Connection pattern file] dialogue is displayed.
2 Click the [Save] button.
The [Input file name] dialogue is displayed.
3 Input the file name using the software full keyboard.
4 Click the [OK] button.
The connection pattern is saved, and the connection pattern name is displayed in the
[Connecting pattern files] dialogue.
Memo
The number of connection patterns that can be saved is up to 10 apart from the connection
pattern set at the time of shipment from the factory (default).
The pattern that is set at factory delviery (Default) cannot be changed.
■ Loading a connection pattern
1 Click the [Save/Load file] button of the [Inter Switch] dialogue box.
The [Connecting pattern files] dialogue is displayed.
2 Click the connection pattern to be loaded.
3 Click on the [Load] button.
The loaded connection pattern is displayed in the [Inter Switch] dialogue.
■ Deleting a connection pattern file
1 Click the [Save/Load file] button of the [Inter Switch] dialogue box.
The [Connecting pattern files] dialogue is displayed.
2 Click the connection pattern to be deleted.
3 Click the [Delete] button.
A dialogue box for confirmation of deleting is displayed.
4 Click the [OK] button in the dialogue box to delete.
The selected connecting pattern file is deleted.