12-5 Section 12 Setting up Alerts
12.5 RADAR Alarm Issuing Conditions
[Operation procedure]
Open the RADAR Alarm issuing condition setting screen by performing the following menu operations.
[Menu] button → Alert → RADAR Alarm
In this dialogue, set a RADAR Alarm issuing range.
The following table shows the setting items.
RADAR Alarm Mode Set a condition for issuing an alarm.
In: A “RADAR Alarm (In)” alarm is issued while a
target (echo) exists within the alarm range.
Out: A “RADAR Alarm (Out)” is issued while a
target (echo) exists outside of the alarm range.
In / Out
Detection Level Set a signal level of the radar echo that is
1 (Low) / 2 / 3 / 4 (High)
[Sector] tab
Set a Sector alarm issuing range.
1/2 tab A sector to be set can be selected from Sector 1 or
1 / 2
Use Sector 1 / Use
Set a sector alert to On/Off. When this item is set
to Off, the Sector is hidden.
On: Select
Make Sector 1 / Make
Sector 2
The cursor mode is set to a sector creation mode.
When the [Make Sector] button is pressed and the
[Use Sector 1 / Use Sector 2] check box is Off, the
item is set to On automatically.
-
Set a sector start angle.
°
°
Set a sector start distance.
End Distance Set a sector end distance.
A sector end distance can be set under the
conditions where the distance width from the start
distance is within the range from 0.50 NM to 2.00
1.5 NM to 32.0 NM