Section 13 Setting up the Operation Mode 13-16
13.11 Setting Operation Tests
Set information on operation tests.
[Operation procedure]
Open the operation test setting screen by performing the following menu operations.
[Menu] button
Settings TT Test
Setting Item Description of Setting Setting Value
Test Video Set up the type of test video. Off / VDIN
TT Simulator Set up the scenario of the TT Simulator mode. Off / Scenario1 /
Scenario 2 / Scenario 3 /
Scenario 4 / Scenario 5 /
Scenario 6
Gate Display
Switch between On/Off of the Gate Display
mode.
To enable: Select.
To disable: Clear.
Vector Constant Set up the vector's tracking performance. 1 to 8
VD Level Mode
(Manual)
Display the threshold value display method of the
quantization mode at manual acquisition.
AUTO Threshold1
AUTO Threshold 2
Manual Threshold
VD Level (Manual)
Set up the quantization level when acquiring
manually.
0 to 255
VD Level (AUTO)
Set up the quantization level when acquiring
automatically.
0 to 255
Gate Size Display the gate size to be used for tracking. Small / Medium / Large
Tracking
The number of currently acquired targets is
displayed in a range from 0 to the maximum TT
display count.
-

Table of Contents