EasyManua.ls Logo

JRC JMR-5425-9X - Setting up the Automatic Acquisition; Activation Zone (AZ); Using [New Target Warning] Dialogue Box in the [Alert] Menu

JRC JMR-5425-9X
640 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 6 Target Tracking and AIS 6-20
6.5.2 Setting up the automatic acquisition/
activation zone (AZ)
Auto acquisition/activation zone has the shape of sector set up according to the angle and distance as
shown in the following figure.
AUTO acquisition/activation zone (AZ) is set up using the following three methods.
(1) Set
by selecting [Alert]
- [New T
arget Alarm].
(2) Use
the cursor.
(3) Use the EBL/VRM dial.
6.5.2.1 Using [New Target Warning] dialogue box in the [Alert]
menu
[Operation procedure]
Open the target acquisition alarm setup screen by performing the following menu operations.
[Menu] button Alert New Target Alarm
1 To set up AZ1, select the [Use AZ1] check box. To set up AZ2, select the [Use AZ2]
check box.
2 To set up [Use AZ1], click on the [1] tab. To set up [Use AZ2], click on the [2] tab.
Their respective setting items are displayed.
3 Select [Start Angle], [End Angle], [Start Distance], and [End Distance] of AZ and enter
the information from the numeric value input keyboard.
Start Angle
AZ1
AZ2
Start Distance
End Distance
End Angle
Example of AUTO acquisition/activation zone (AZ)