Section 4 Range and Bearing Measurement Methods 4-8
4.5 Using the Electronic Bearing Line
(EBL) and Variable Range Marker
(VRM)
4.5.1 Measuring a range and a bearing with EBL and
VRM
4.5.1.1 Measuring a range and a bearing with the trackball
section of the operation unit
When the cursor is in AUTO mode, EBL and VRM can be operated on the trackball section of the
operation unit.This section describes the manipulation under EBL1 and VRM1; however, the same
manipulation can be performed under EBL2 and VRM2 also.
Memo
To manipulate the EBL/VRM, the RADAR transmission status must be Transmit”.
1 Enable the manipulation of EBL1 by clicking on the [EBL1] button.
2 Enable the movement of EBL1 by clicking on the EBL1 line.
3 Align the cursor with a target and click on the mouse button.
The bearing of the target is displayed on the [EBL1] button.
4 Enable the manipulation of VRM1 by clicking on the [VRM1] button.
5 Enable the movement of VRM1 by clicking on the VRM1 circle.
6 Align the cursor with a target and click on the mouse button.
The range of the target is displayed on the [VRM1] button.
[EBL1] button
[VRM1]
button