Section 12 Setting up Alerts 12-8
12.7 Setting up Alert Processing
[Operation procedure]
Open the [AMS] dialogue by performing the following menu operations.
[Menu] button Alert AMS
In this dialogue, the time to activate the action at the next stage when acknowledge is not performed
for an alert can be set up.
Enter a wait time up to the issuing of an alert of the next stage in each [Time Limit].
[Reactivation of Silenced Alert]
[Time Limit]:
Set, in a range between 0 and 60 s., the time required to reactivate the alert sound that was silenced
temporarily.
[Transfer to BNWAS]
[Time Limit]:
When a BNWAS (Bridge Navigational Watch Alarm System) is connected, specify the time to transfer
an unacknowledged alert to the BNWAS in a range between 0 and 60 s.
[Repetition of UNACK Warning]
[Time Limit]:
Specify the time to regenerate an unacknowledged warning as an alert sound in a range between 0
and 300 s. A warning will be generated repeatedly until it is acknowledged.