14.3.2.3 To change the communication settings of the serial port
Display the [Detail] dialogue by clicking on the [Detail] button of the serial port that is enabled.
The setting targets can be checked with the [Source Device] display, the [Terminal] display, and the
[Sensor] display ([Gyro Sensor] display and the [Log Sensor] display when NSK is selected).
Set the items that are shown in the following table and click on the [Set] button.
Setting Item
Description of Setting
Setting Value
Baud Rate Selects the baud rate of the serial port on the combo
box.
Selectable baud rates
vary depending on the
serial port (refer to
"Selectable baud rates").
Stop Bits Selects the stop bit length of the serial port from the
combo box.
1 / 2
Checksum Selects the check box and enable the checksum of the
sentence of the corresponding serial port.
To enable: Select.
To disable: Clear.
Data Length Selects the data length of the corresponding serial port
from the combo box.
5 / 6 / 7 / 8
Buffer Size Enters the buffer size of the corresponding serial port
in the box.
0 to 10240 byte
Parity Selects the parity of the corresponding serial port from
the combo box.
None / Odd / Even
Time Out Enters the time-out duration of the corresponding
serial port in the box.
0 to 999 s
Sentence Specifies the alert sentence type.
When "-" is selected, no alert is selected.
- / ALR / ALF
Transmit Interval Displayed only when [Alert (to BNWAS)] is selected as
the sensor.
Set an alert transmission interval within the range from
1 second to 30 seconds.
1 to 30
HBT check box Displayed in the case other than the case where [Alert
(to BNWAS)] is selected as the sensor.
Enables/disables the setting of HBT transmission
interval.
To enable: Select.
To disable: Clear.
Transmit Interval Sets the HBT transmission interval within the range
from 1 second to 30 seconds.
1 to 30
Selectable baud rates
Serial port
Baud rate
Serial point on RPU
GPS
Fixed to 4800
Gyro Compass
1200/2400/4800/9600/19200/38400
Serial port on the built-in SLC
CH1-4
2400/4800/9600
CH5/6
2400/4800/9600/19200/38400
Gyro
Fixed to 38400
Serial port on SLC1/SLC2
CH1-8 2400/4800/9600
CH9/10
2400/4800/9600/19200/38400