14-5
Section 14 Adjusting and Setting up Equipment (for Services)
14.2.2.3 Adjusting a tuning peak value
Adjust a tuning indication and an echo peak.
Memo
• Disabled in radar slave mode.
• Displayed under 10 kW radar (NKE-2103-4/6/6HS) only.
1 Adjust the tuning indication bar as described in “14.2.2.2 Setting a tuning bar peak
value”.
2 Set the range to 48 nm or more.
3 Click on the [Tune Peak Adjustment] (adjustment peak value) input box.
A numerical value input keyboard is displayed.
4 Adjust the tuning peak adjustment value so that the radar image becomes strongest
when the tuning indication at the top left corner of the screen points to the maximum.
For the method of using the numerical value input keyboard, refer to “3.19.2 Name and function
of each section of the keyboard”.
14.2.2.4 Setting bearing pulse output
1
From the [Output BP] combo box, select a bearing pulse count (2048 or 4096) that is
output from the radar antenna.