14-7
Section 14 Adjusting and Setting up Equipment (for Services)
1
14
14.2.3.2 Adjusting a performance monitor of magnetron radars
(NKE-2103/1130)
On the [Performance Monitor] dialogue, adjust a magnetron radar transmitting/receiving status while
checking the performance monitor level.
Adjusting a monitor reception level
Adjust the circuit for monitoring the radar equipment reception performance.
1 Click on the [MON Adjustment] (performance monitor adjustment) input box.
A numeric value input keyboard is displayed.
2 Enter a setting value in the input box so that the farthest position of the performance
monitor pattern becomes 18.00 NM. (0 to 127)
For the method of using the numeric value input keyboard, refer to "3.19.2 Name and function
of each section of the keyboard".
Adjusting a monitor transmission level
Adjust the circuit for monitoring the radar equipment transmission performance.
1 Click on the [MON Indicator Adjustment] (performance monitor indicator adjustment)
input box.
A numeric value input keyboard is displayed.
2 Enter a setting value so that the MON level indicates "8" (0 to 127).
For the method of using the numeric input keyboard, refer to "3.19.2 Name and function of each
section of the keyboard".
Adjust to 8.
18.00 NM
Performance monitor pattern