14-17 
Section 14 Adjusting and Setting up Equipment (for Services)
 
 
 
 
 
 
Table A: Sensors that can be selected by serial ports on RPU 
 
Serial port  Sensor name 
GPS  GPS 1 
*1
GPS 3
*1
 
*1
Gyro Compass    Heading Sensor1 
Heading Sensor2 
NSK 
*Since the following combo boxes are enabled when NSK is selected, select a 
Heading Sensor to be connected to NSK and Log.   
Heading Sensor 
Heading Sensor2 
Log  Log1 
*1
 May not be displayed depending on the number of GPS units 
 
[Setting a serial port of built-in SLC] 
Set CH1 to CH6 and gyro serial ports that are directly assigned to the display as shown below.   
CH1 to CH6  1.  Select the [RPU] tab. 
2.  Enable the serial port of the channel by selecting the 
check box. 
3.   Select a sensor
*1
 to be connected to the channel on 
the [Sensor] combo box. When not selecting a 
To enable: Select. 
To disable: Clear. 
Gyro  1.  Select the [RPU] tab. 
2.  Enable the serial port of the channel by selecting the 
[Gyro] check box.   
3.  In the [Sensor] combo box, select the sensor to be 
connected to the Gyro serial port. When not 
selecting a sensor, select [-].   
To enable: Select. 
To disable: Clear. 
 
Selectable sensors:   
Heading Sensor1(NMEA) 
*1
 The following sensors can be selected on the built-in SLC (CH1 to CH6).   
However, the sensors that can be actually selected vary depending on the equipment setting. 
AUTO, Heading Sensor 1, Heading Sensor 2, Log 1, Log 2, GPS 1, GPS 2, GPS 3, GPS 4, Ship’s 
Clock, Echo Sounder 1, Echo Sounder 2, AIS, NAVTEX, Anemometer, Water Temperature Metre, 
Current Metre, Climate Metre, ROT Indicator, Rudder, RADAR1(TT RX), RADAR2(TT RX), Alert(to 
BNWAS), GPS Buoy, WPT(from Plotter)