EasyManua.ls Logo

JUKI IP-420 - Safety Switch; Installing the Throat Plate Auxiliary Cover

JUKI IP-420
133 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 6 –
3-6. Installing the throat plate auxiliary cover
[When using area 1306]
1) Temporarily x throat plate auxiliary
cover supports A
2
and B
3
to the
machine bed with setscrews (M5)
6
.
2) Move the cloth feed base to the rear,
and place throat plate auxiliary cover
1
from between lower plate
7
and
throat plate
8
. At this time, be careful
not to bend lower plate
7
.
3) Fix throat plate auxiliary cover
1
with
throat plate auxiliary cover setscrews
5
and washers
4
.
1
4
3
5
6
2
4
8
7
[Area 1306]
3-5. Safety switch
1
Remove tape
2
xing the lever section of safety
switch
1
.
1. When using the safety switch
without removing tape
1
, it is very
dangerous since the sewing ma-
chine works even in the state that it
is tilted.
2. In case error 302 occurs when the
sewing machine works after setup,
loosen the safety switch
2
tting
screw with a screwdriver, and lower
the switch to the downside of the
sewing machine.
2
WARNING :
Be careful not to bump your head or any other parts of your body against the throat plate auxiliary
cover when you bend over your work.

Table of Contents