– 109 –
Error code
Display Description of error Display message
How to recover
Place of
recovery
E917
Communication failure
between operation panel
and personal computer
When abnormality occurs in
data communication.
Possible
to re-start
after reset.
E918
MAIN p. c. b. overheat
Overheat of MAIN p. c. b.
Turn ON the power again
after taking time.
Turn OFF
the power
E925
Intermediate presser
motor origin retrieval error
Origin sensor of intermediate
presser motor does not
change at the time of origin
retrieval.
Turn OFF
the power
E926
X motor position slip error
1. In case
of error
display
during
sewing
 
Possible to
re-start after
reset
2. In case
of error
display
after end
of sewing
 
Possible
to re-start
after reset
3. In case of
others
 
Turn OFF
the power.
1. Step
screen
2. Sewing
screen
3. -------
E927
Y motor position slip error
1. In case
of error
display
during
sewing
 
Possible to
re-start after
reset
2. In case
of error
display
after end
of sewing
 
Possible
to re-start
after reset
3. In case of
others
 
Turn OFF
the power.
1. Step
screen
2. Sewing
screen
3. -------