Table 62: Chassis Component Alarm Conditions on EX4200
Switches (continued)
Remedy
Alarm
SeverityAlarm Condition
Chassis
Component
•
Check the room temperature.
•
Check the fan.
•
If the above two checks show no
problems, open a support case using the
Case Manager link at
http://www.juniper.net/support/ or
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the United
States).
Major
(red)
The temperature
inside the chassis
has exceeded
203° F (95° C).
Temperature
•
Replace the fan tray.
•
Open a support case using the Case
Manager link at
http://www.juniper.net/support/ or
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the United
States).
Major
(red)
The temperature
inside the chassis
has exceeded
185° F (85° C) and
a fan has failed.
•
Check the room temperature.
•
Check the fan.
•
If the above two checks show no
problems, open a support case using the
Case Manager link at
http://www.juniper.net/support/ or
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the United
States).
Minor
(yellow)
The temperature
inside the chassis
has exceeded
176° F (80° C).
•
Replace the fan tray.
•
Open a support case using the Case
Manager link at
http://www.juniper.net/support/ or
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the United
States).
Minor
(yellow)
The temperature
inside the chassis
has exceeded
158° F (70° C) and
a fan has failed.
Open a support case using the Case Manager
link at http://www.juniper.net/support/
or call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the United
States).
Major
(red)
The temperature
sensor has failed.
Copyright © 2017, Juniper Networks, Inc.228
EX4200 Switch Hardware Guide

Table of Contents

Other manuals for Juniper EX4200-24T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4200-24T and is the answer not in the manual?

Juniper EX4200-24T Specifications

General IconGeneral
BrandJuniper
ModelEX4200-24T
CategorySwitch
LanguageEnglish

Related product manuals