TECHNICAL DESCRIPTION Kamstrup 162M/382M
5512-1040 GB/05.2012/Rev. C1
35
4.11 Display read-out of load profile logger
The meters enable readout of the load profile logger on the display via a push button on the meter. Figure 14
shows a block diagram of the read-out. ”S” means a short push, ”L” means a long push, and ”LL” means an extra
long push.
”Last profil”
Obis = ”P.01"
Reg BReg A Reg C
SSS
L
S
Logger
readout
Set time
and
date
Flash
Info = 1 sec
Reg = 3 sec
No flash
L
Timeout = 2 min
Step out
of DCT
Reg 1
L
L
L
L/LL
Log ID
S
Obis = time
If ”hour log” hh.00.00, else
hh.mm.00
Value = date (YY-MM-DD)
LL
L
S
Obis = ”Year”
Value: date (YY-
MM-DD)
S
Year (YY) --
L
S
Month (MM) --
L
S
Day (DD) --
L
S
Hour (hh) --
S
Minute(mm) -=
delta log time
”hour log”?
TrueFalse
LL
LL
LL
LL
LL
Obis = ”Month”
Value: date (
YY-MM-DD)
Obis = ”Day”
Value: date (
YY-MM-DD)
Obis = time (hh.mm.00)
Value: ”Hour”
LL
LL
LL
Display: ”End”
Read time and date
Minute -= %delta log
time
Obis = hh.mm.00
Value: YY-MM-DD
Info
Obis = Obis code
Value: Reg value
Reg
Reg 2
Reg n
S
S
Reg 1
L
L
L
Reg 2
Reg n
S
Reg 1
L
L
L
Reg 2
Reg n
S
S
Log ID -”1 log”
Log ID – ”n log”
L
Obis = time (hh.mm.00)
Value: ”Minute”
Timeout = 2 min
Step out
of DCT
Configuration
check
Step out
of DCT
True False
Config
registers to
log != 0
LoadProfile-
Logger on?
Step out
of DCT
L/LL
S
Display: ”Log off”
True
False
L/LL
S
Display: ”No reg”
Timeout = 2 min
Step out
of DCT
Log
found?
True
False
S
S
S
Display: ”Error”
L/LL
End:
Year:
Month:
Day:
Hour:
Minute:
No reg:
Error:
Log off:
Display words:
Figure 14: Block diagram of the display read-out.
See the following page for an example of a display read-out of an A+-meter.