EasyManuals Logo

KEB COMBIVERT S4 User Manual

KEB COMBIVERT S4
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
E 33
ANTRIEBSTECHNIK
Behaviour at External Fault
This parameter determines the
response of the drive to an external
fault.
Setting range: 0…6
Resolution: 1
Factory setting: 0
Remarks: ENTER-Parameter
Customer setting:
Value Response of Drive
0 Error message: E.EF Immediate disconnection of inverter!
!
To restart eliminate the fault and make a
Reset !
1 Status message: A.EF Fast stop Disconnection of inverter after
attaining speed 0.
!
To restart eliminate the fault and make a
Reset !
2 Status message: A.EF Fast stop Holding torque at speed 0.
!
To restart eliminate the fault and make a
Reset !
3 Status message: A.EF Immediate disconnection of inverter.
!
Automatic restart when fault condition no longer exists
!
4 Status message: A.EF Fast stop Disconnection of inverter after
attaining speed 0.
!
Automatic restart when fault condition no longer exists
!
5 Status message: A.EF Fast stop Holding torque at speed 0.
!
Automatic restart when fault condition no longer exists
!
6 Status message: none No effect on the drive.
!
Fault is ignored
!
Permits the shifting of the setpoint-speed characteristic.
Offset REF 1
n
max
"forward"
n
max
"reverse"
+10 V
-10 V
3)
2) 1)
Setting range: -100…+100 %
Resolution: 0,1 %
Faxtory setting: 0 %
Customer setting: %
Examples:
Characteristic 1: CP.16 = 0% (standard setting)
0V = 0 U/min
Rotation "forward":n
max
is attained at +10V
Rotation "reverse":n
max
is attained at -10 V
Characteristic 2: CP.16 = +40%
0V = 40 % of n
max
"forward"
Rotation "forward":n
max
is attained at 60% of +10V
Rotation "reverse":maximal 60% of n
max
possible
Characteristic 3: CP.16 = –70%
0V = 70 % of n
max
"reverse"
Rotation "forward":maximal 30% of n
max
possible
Rotation "reverse":n
max
is attained at 30% of -10V
8. Parameter Description
Adjustment of parameter
CP.7 and CP.8 must be
observed!

Questions and Answers: