FORMat:READing:TIME:TYPE {ABSolute|RELative}
FORMat:READing:TIME:TYPE?
Selects the time format (absolute or relative) for time stamp returned when FORMat:READing:TIME is enabled.
Parameter Typical return
{ABSolute|RELative}
Default: RELative
ABS or REL
Enables the absolute time format:
FORM:READ:TIME:TYPE ABS
FORM:READ:TIME ON
The time format setting will be disabled (Off) after a Factory Reset (*RST command).
In terms of reading stored data from reading memory, the relative format is considerably faster than the absolute
format.
Absolute format is based on the instrument's real-time clock as set by the SYSTem:DATE and SYSTem:TIME com-
mands.
FORMat:READing:UNIT {OFF|ON}
FORMat:READing:UNIT?
Enables (On) or disables (Off) the inclusion of measurement units (VAC, VDC, OHM, etc.) in the reading format.
Parameter Typical return
{OFF|ON}
Default: OFF
0 (OFF) or 1 (ON)
Enables the inclusion of measurement units in the reading format:FORM:READ:UNIT ON
The unit setting will be disabled (Off) after a Factory Reset (*RST command).
Keysight DAQ970A/DAQ973A Programming Guide 141
2 SCPI Programming

Table of Contents

Other manuals for Keysight Technologies DAQ970A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies DAQ970A and is the answer not in the manual?

Keysight Technologies DAQ970A Specifications

General IconGeneral
BrandKeysight Technologies
ModelDAQ970A
CategoryMultiplexer
LanguageEnglish