EasyManua.ls Logo

Keysight Technologies DAQ970A - Page 141

Keysight Technologies DAQ970A
393 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FORMat:READing:TIME:TYPE {ABSolute|RELative}
FORMat:READing:TIME:TYPE?
Selects the time format (absolute or relative) for time stamp returned when FORMat:READing:TIME is enabled.
Parameter Typical return
{ABSolute|RELative}
Default: RELative
ABS or REL
Enables the absolute time format:
FORM:READ:TIME:TYPE ABS
FORM:READ:TIME ON
The time format setting will be disabled (Off) after a Factory Reset (*RST command).
In terms of reading stored data from reading memory, the relative format is considerably faster than the absolute
format.
Absolute format is based on the instrument's real-time clock as set by the SYSTem:DATE and SYSTem:TIME com-
mands.
FORMat:READing:UNIT {OFF|ON}
FORMat:READing:UNIT?
Enables (On) or disables (Off) the inclusion of measurement units (VAC, VDC, OHM, etc.) in the reading format.
Parameter Typical return
{OFF|ON}
Default: OFF
0 (OFF) or 1 (ON)
Enables the inclusion of measurement units in the reading format:FORM:READ:UNIT ON
The unit setting will be disabled (Off) after a Factory Reset (*RST command).
Keysight DAQ970A/DAQ973A Programming Guide 141
2 SCPI Programming

Table of Contents

Other manuals for Keysight Technologies DAQ970A