1 Quick Reference
10 Keysight N6700 User’s Guide
Model Differences
(
= available)
50 W output rating
N6731B – N6736B
N6751A
N6761A
100 W output rating
N6741B – N6746B
N6752A
N6762A
300 W output rating
N6773A – N6777A
N6753A, N6754A
N6763A, N6764A
500 W output rating
N6755A, N6756A
N6765A, N6766A
Output disconnect relays
Option 761
Option 761
Option 761
Output disconnect/polarity reversal relays
NOTE 1
Option 760
Option 760
Option 760
Autoranging output capability
Voltage or current turn-on priority
N6761A, N6762A
Precision voltage and current measurements
Low voltage and low current output range
N6761A, N6762A
Low voltage and low current measurement range
200 microampere measurement range
NOTE 2
Option 2UA
Simultaneous voltage and current measurements
SCPI command output list capability
NOTE 3
Option 054
Option 054
SCPI command array readback
NOTE 3
Option 054
Option 054
SCPI command programmable sample rate
NOTE 3
Option 054
Option 054
SCPI command external data logging
NOTE 3
Option 054
Option 054
Double-wide (occupies 2 channel locations)
N6753A – N6756A
N6763A – N6766A
Source/Measure Units (SMU)
(
= available)
Output rating
20 W
20 W
20 W
80 W
80 W
24 W
18 W
2-quadrant operation
4-quadrant operation
Auxiliary voltage measurement input
●
●
Output disconnect relays
Option 761
Option 761
Negative voltage protection
Voltage or current priority mode
Programmable output resistance
Multiple voltage output ranges
3
3
3
4
4
Multiple current output ranges
3
3
4
4
4
Multiple voltage measurement ranges
3
3
3
Multiple current measurement ranges
4
4
4
3
3
2
2
Simultaneous voltage and current measurements
Seamless measurement autoranging
SCPI command output list capability
NOTE 3, 4
SCPI command array readback
NOTE 3
SCPI command programmable sample rate
NOTE 3
SCPI command external data logging
NOTE 3
Double-wide (occupies 2 channel locations)
1
Output current is limited to 10A max. on Models N6742B and N6773A with Option 760.
Option 760 is not available on Models N6741B, N6751A, N6752A, N6761A, and N6762A.
2
Option 2UA.is only available on Models N6761A and N6762A. It includes Option 761.
3
Only available when using the remote interfaces; not from the front panel.
4
List capability is not available on the negative current output on Model N6783A