Error Codes 5
-113 "Undefined header"
[The header is syntactically correct, but it is undefined for this specific device; for example, *XYZ is
not defined for any device.]
-114 "Header suffix out of range"
-115 "Unexpected number of parameters"
-120 "Numeric data error"
[This error, as well as errors -121 through -129, are generated when parsing a data element which
appears to be numeric, including the nondecimal numeric types. This error message is used if the
device cannot detect a more specific error.]
-121 "Invalid character in number"
[An invalid character for the data type being parsed was encountered; for example, an alpha in a
decimal numeric]
-123 "Exponent too large"
[The magnitude of the exponent was larger than 32000 (see IEEE 488.2,7.7.2.4.1).]
-124 "Too many digits"
[The mantissa of a decimal numeric data element contained more than 255 digits excluding
leading zeros (see IEEE 488.2, 7.7.2.4.1).]
-128 "Numeric data not allowed"
[A legal numeric data element was received, but the device does not accept one in this position for
the header.]
-130 "Suffix error"
-131 "Invalid suffix"
[The suffix does not follow the syntax described in IEEE 488.2, 7.7.3.2, or thesuffix is inappropriate
for this device.]
-134 “Suffix too long”
[The suffix contained more than 12 characters (see IEEE 488.2, 7.7.3.4).]
-138 “Suffix not allowed
[A suffix was encountered after a numeric element which does not allow suffixes.]
-140 "Character data error"
-141 “Invalid character data”
[Either the character data element contains an invalid character or the particular element received
is not valid for the header.]
-144 "Character data too long"
-148 “Character data not allowed”
[A legal character data element was encountered where prohibited by the device.]
Error
Number String

Table of Contents

Other manuals for Keysight N774 C Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight N774 C Series and is the answer not in the manual?

Keysight N774 C Series Specifications

General IconGeneral
BrandKeysight
ModelN774 C Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals