106
60980008
Homing_Metho
d
33
01 2F 98 60 00 21 00 00 00 B7
Homing_Speed_Zero
fault unit is DEC
DEC=[(RPM*512*E
ncoder
resolution)/1875]
60990120
Homing_Speed_
Switch
200RPM
01 23 99 60 01 55 55 08 00 30
60990220
Homing_Speed_
Zero
150RPM
01 23 99 60 02 00 40 06 00 9B
60400010
Controlword
1F
01 2B 40 60 00 1F 00 00 00 15
01 40 41 60 00 00 00 00 00 1ERead state wordC037means home found
Position modeControlword Absolute positioning 2F to 3F Relative positioning 4F to 5F103F Start absolute
positioning)
CANOpen
Name
Value
MessageID=1
Meaning
60400010
Controlword
F
01 2B 40 60 00 0F 00
00 00 25
DEC=[(RPM*512*Enco
der resolution)/1875]
60600008
Operation_mode
1
01 2F 60 60 00 01 00
00 00 0F
607A0020
Target_Position
50000inc
01 23 7A 60 00 50 C3
00 00 EF
60810020
Profile_Speed
200RPM
01 23 81 60 00 55 55
08 00 49
60830020
Profile_Acc
610.352rps/s
Default
DEC=[(RPS/S*
65536*Encoder
resolution)/1000/4000]
60840020
Profile_Dec
610.352rps/s
Default
60400010
Controlword
2F
01 2B 40 60 00 2F 00
00 00 05
3F(Absolute
positioning)
01 2B 40 60 00 3F 00
00 00 F5
4F
01 2B 40 60 00 4F 00
00 00 E5
5F(Relative
positioning)
01 2B 40 60 00 5F 00
00 00 D5
01 40 41 60 00 00 00 00 00 1E Read state wordD437 means position to
Speed mode
CANOpen
Name
Value
MessageID=1
Meaning
60600008
Operation_Mode
3
01 2F 60 60 00 03 00 00 00 0D
Default unit of Target
speed
DEC
DEC=[(RPM*512*Enc
60FF0020
Target_Speed
150RPM
01 23 FF 60 00 00 40 06 00 37
60400010
Controlword
F
01 2B 40 60 00 0F 00 00 00 25
60830020
Profile_Acc
610.352
rps/s
Default

Table of Contents