70
SMH40S-0010-30AXK-4LKH
0.265
SMH60S-0020-30AXK-3LKX
0.48
CD422S-AA-000
15
SMH60S-0040-30AXK-3LKX
0.48
SMH80S-0075-30AXK-3LKX
0.662
SME60S-0020-30AXK-3LKX
0.48
SME60S-0040-30AXK-3LKX
0.48
SME80S-0075-30AXK-3LKX
0.662
SMH80S-0100-30AXK-3LKX
0.562
CD432S-AA-000
27.5
SMH110D-0105-20AXK-4LKX
0.992
SMH110D-0126-20AXK-4LKX
1.058
SMH130D-0105-20AXK-4HKX
1.1578
SMH130D-0157-20AXK-4HKX
1.191
SMH110D-0126-30AXK-4HKX
1.058
CD622S-AA-000
25
SMH110D-0157-30AXK-4HKX
0.992
SMH110D-0188-30AXK-4HKX
1.058
SMH130D-0105-20AXK-4HKX
1.1578
SMH130D-0157-20AXK-4HKX
1.191
SMH130D-0210-20AXK-4HKX
1.3232
SMH150D-0230-20AXK-4KHX
1.65
7.3.4 Examples of Analog Torque Mode
In the analog torque mode, follow the steps below to configure a driver:
Step 1: Confirm whether it is necessary to enable the driver through external digital input ports. To enable the
driver through external digital input ports, see Table 6-12 in Example 6-3 for settings. If the driver does not
require enabling through external digital input ports, you can disable the enabling function of external digital
input ports by referring to Table 6-13 of Example 7-3, and enable the auto power-on function of the driver by
setting its internal parameters.
Step 3: Confirm mode switching positions and operation modes by referring to the settings in Example 6-5.
The factory default settings for the driver are as follows: When no signal is inputted to DIN3, the driver
operates in the ―-4‖ mode (d3.16 = -4); when signal is inputted to DIN3, the driver operates in the -3‖ mode
(d3.17 = -3). If the driver is required to operate in the torque mode (―4‖ mode), please set d3.16 or d3.17 to 4.
In case d3.16 = 4, if DIN3 has no input signals when the driver is powered on, the driver operates in the ―4‖
mode. In case d3.17 = 4, if DIN3 has input signals, the driver operates in the ―4‖ mode.
Step 3: After configuring functions on digital input ports, select the analog torque channel, and set
parameters such as analog torque factors, dead zone, offset, filtering, speed limit factors, and max speed
limits.
Step 4: Save parameters.