2. Press ENTER. The interface for selecting addresses is displayed.
3. Press ▲ to adjust data as d3.35.
4. Press ENTER to display the current value d3.35. Press ENTER again to modify the value d3.35. In this case,
the 1
st
number at the right side is flickering. Short press MODE for three times to move to the first position on
the left. Then press ▲. The value is increased to 9000. In this case, the current data is decimal.
5. Press ▲ again. The content of numeric display changes to ―271.0‖, and the 3
rd
decimal point (from left to
right) flickers. In this case, the data is hexadecimal. Press ENTER to confirm the current value. The 1
st
decimal point on the right flickers. In this case, the denominator of the electronic gear ratio is modified to
10000.
Fig. 4-2 Number system conversion
Example 4-2: Set the speed to 1000 RPM/-1000 RPM with separate regulation of
bits
1. Press MODE. The main menu is displayed. Choose F000.
2. Press ENTER. The interface for selecting addresses is displayed.
3. Press ▲ to adjust data as d0.02.
4. Press ENTER to display the current value d0.02. Press ENTER again to modify the value d0.02. In this case,
the 1
st
number at the right side is flickering.
5. Short press MODE for three times to move to the 1
st
position on the left. Press ▲ to modify the value to 1.
Press ENTER to confirm the current value. The 1
st
decimal point on the right flickers. In this case, the speed
is 1000 RPM.
6. Press ▼ to modify the value to -1. In this case, the 1
st
decimal point on the left flickers, indicating that the
current data is negative. Press ENTER to confirm the current value. The 1
st
decimal point on the right flickers.