3. Common cathode connection (to controllers that support valid high level output)
Fig. 7-4 Common cathode connection (to controllers that support valid high level output)
7.1.2 Parameters for Pulse Control Mode
1. Parameters for electronic gear ratio
Table 7-1 Parameters for electronic gear ratio
Numeric
Display
Variable Name
Meaning
Default Value
Range
d3.34
Gear_Factor
Numerator of electronic
gear 0 in mode -4
1000
-32767~32767
d3.35
Gear_Divider
Denominator of electronic
gear 0 in mode -4
1000
1~32767
Parameters for electronic gear ratio are used to set the numerator and denominator of electronic gears when
the driver operates in mode -4.
Command pulse input Command pulse output
F1 F2
Namely: F2=
DividerGear
FactorGear
_
_
* F1
If the electronic gear ratio is 1:1, 10000 pulses are inputted externally (the resolution of encoders is 2500
PPR, quadruple), and the motor turns a circle. If the electronic gear ratio is 2:1, 10000 pulses are inputted
externally, and the motor turns two circles.
2. Parameters for pulse mode selection
Table 7-2 Parameters for pulse mode selection
Numeric
Variable Name
Meaning
Default
Range
DividerGear
FactorGear
_
_